Discussion:
Filter for CAN Identifier
(too old to reply)
oggy82
2008-07-10 15:40:16 UTC
Permalink
Hi,
 
i want to filter the received CAN identifier. I use Labview 8.0 and NI-CAN 2.5.2 with PCI 1 Port Series 2 Hardware. I have tried the example program for filtering incoming CAN identifier. Whatever I set, every message was filtered or only messages with the ID 25xxxxxx wasn't filtered. I have tried the single and duale extended filter. I hope someone has got an idea or know how to configure the filter.
DirkW
2008-07-10 15:40:16 UTC
Permalink
See the attached examples for how to configure the filter settings.
DirkW


filter_series2_example.zip:
http://forums.ni.com/attachments/ni/30/3597/1/filter_series2_example.zip
oggy82
2008-07-10 20:40:08 UTC
Permalink
Hi,
sorry Dirk I 'am not able to open this file.  This file is maybe damaged, can you upload again?
Thanks
DirkW
2008-07-11 14:10:10 UTC
Permalink
I could open it? here is another try. I ziped it with another tool.
DirkW


SJA_Filter_series2.zip:
http://forums.ni.com/attachments/ni/30/3600/1/SJA_Filter_series2.zip
oggy82
2008-07-15 19:40:05 UTC
Permalink
Hi,
Yes I can open the zip file, and the filter settings works. Thanks, now I know how to configure the filter.